|
HP Integrity rx3600 Server |
| |
|
HP Integrity rx3600 System Overview (Interior View)
|
|
|
| 1. |
Hot Swap Fans |
3. |
2 Clamshell CPU Sockets |
| 2. |
8 SAS HDDs |
4. |
8 or 24 DDR2 DIMM Slots |
| HP Integrity rx3600
|
 |
| 1. |
8 Hot Plug PCI-X IO Slots (2 @ 266 MHz) |
2. |
Redundant Bulk Power |
HP Integrity Systems Standard Features
| Minimum System |
- One 64 bit dual core Intel Itanium processor; either 1.6 GHz/18
MB cache or 1.4 GHz/12 MB cache; or 1.66 GHz/18 MB 9140M processor
or 1.42 GHz/12 MB 9120N processor
- One I/O backplane. Either PCI X 2.0 backplane with eight
available slots or PCI Express backplane with 8 available slots
- 2 GB PC2 4200 ECC x4 Single rank Registered DDR2 SDRAMs (4×512MB
DIMMs)
- Eight DIMM slots (2×4 DIMM slot memory carrier boards)
- One hot swap power supply
|
|
| Maximum Server Capacities |
- Two dual core 64 bit Intel Itanium processors; either 1.6 GHz/18
MB cache or 1.4 GHz/12 MB cache; or 1.66 GHz/18 MB 9140M processor
or 1.42 GHz/12 MB 9120N processor
- One I/O backplane. Either PCI X 2.0 backplane with eight
available slots or PCI Express backplane with 8 available slots
- 96 GB PC2 4200 ECC x4 Single rank Registered DDR2 SDRAMs (24×4GB
DIMMs)
- 24 DIMM slots (2×12 DIMM slot memory carrier boards)
- Eight Serial Attached SCSI (SAS) disk drive
- Two hot swap power supplies (two supplies enables redundancy)
|
|
| Standard System Features |
- Operating System support: HP UX 11i version 2 September 2006
Update; HP UX 11i version 3; Linux RHEL 4 U4 and SLES 10; OpenVMS
V8.3 or higher for Integrity servers; and Microsoft Windows Server
2003 Enterprise and Datacenter Edition
- Choice of core storage card.
For HP UX and OpenVMS based systems:
Must select one of two choices: PCI X 8 port Serial Attached SCSI
(SAS) host bus adapter or PCI Express 8 port Smart Array (P400)
Serial Attached SCSI Controller:
- The PCI X 8 port Serial Attached SCSI (SAS) host bus adapter:
Card will be installed in reserved core PCI X I/O slot #1. This card
supports up to two internal RAID 1 volumes (2×2 HDDs) and a disk for
global hot spare, for a maximum of five disks in RAIDed arrays for
HP UX and OpenVMS. All HDDs must be the same size and speed. A
second PCI X 8 Internal Port Serial Attached SCSI host bus adapter
is supported. In this case each adapter is connected up to a maximum
of 4 drives, and the maximum number of disks supported in a RAIDed
array is four. The second PCI X 8. Internal Port SAS host bus
adapter is not available for standard factory installation; it must
be installed via Factory Express or in the field. Use AD348A #006
upgrade product/option to order the second PCI X 8 Internal Port SAS
host bus adapter. When a second PCI X 8 Internal Port SAS host bus
adapter is installed in an rx3600, it must be located in slot #2,
and the LAN adapter moved to slot #10. Please see rx3600 Ordering
Guide for factory configuration details
NOTE: MirrorDisk/UX is
available for SW Mirroring on all HDDs in HP UX based systems and HP
Volume Shadowing Level 1 for HDDs in OpenVMS based systems.
- PCI Express 8 port Smart Array (P400) Serial Attached SCSI
Controller: Requires PCI Express Backplane (AD295A Option 200); card
will be installed in public slot #3, leaving 3 available PCI Express
slots and 4 available PCI X slots. This card supports internal RAID
1, 5 and 6 configurations. RAID 1 requires a minimum of two
identical HDDs, RAID 5 requires a minimum of three identical HDDs,
and RAID 6 requires a minimum of four identical HDDs. (Identical
disks means same size and speed.) Please see rx3600 Ordering Guide
for factory configuration details.
NOTE: MirrorDisk/UX is available for SW Mirroring on all HDDs
in HP UX based systems and HP Volume Shadowing Level 1 for HDDs in
OpenVMS based systems.
For Windows and Linux based systems:
Must select one of three choices: PCI X 8 port Smart Array (P600)
Serial Attached SCSI (SAS) controller, or PCI Express 8 port Smart
Array (P400) Serial Attached SCSI Controller, or PCI Express 16 port
Smart Array (P800) Serial Attached SCSI Controller.
- PCI X 8 port Smart Array (P600) Serial Attached SCSI (SAS)
controller: Card will be installed in reserved core PCI X I/O slot
#1. Supports internal RAID 1, 5 and 6 configurations.. RAID 1
requires two identical HDDs, RAID 5 requires three identical HDDs,
and RAID 6 requires four identical HDDs. Factory set up of RAID 1, 5
and 6 configurations with Smart Array SAS controller is also
supported. Please see rx3600 Ordering Guide for details.
- PCI Express 8 port Smart Array (P400) Serial Attached SCSI (SAS)
controller. Requires PCI Express Backplane (AD295A Option 200); card
will be installed in public slot #3, leaving 3 available PCI Express
slots and 4 available PCI X slots. This card supports internal RAID
1, 5 and 6 configurations. RAID 1 requires a minimum of two
identical HDDs, RAID 5 requires a minimum of three identical HDDs,
and RAID 6 requires a minimum of four identical HDDs. Please see
rx3600
Ordering Guide for factory configuration details.
- PCI Express 16 port Smart Array (P800) Serial Attached SCSI
(SAS) controller: Requires PCI Express Backplane (AD295A Option
200); card will be installed in public slot #3, leaving 3 available
PCI Express slots and 4 available PCI X slots. This card supports
internal and external RAID 1, 5 and 6 configurations.. RAID 1
requires a minimum of two identical HDDs, RAID 5 requires a minimum
of three identical HDDs, and RAID 6 requires a minimum of four
identical HDDs. Please see rx3600 Ordering Guide for factory
configuration details.
- Core PCI X dual port 10/100/1000Base TX LAN (with auto speed
sensing; RJ 45 connector, Wake On LAN support)
- Integrated iLO2 Management Processor for remote management and
HA monitoring
- Telnet and web console via 10/100Base TX management LAN (RJ 45
connector)
- Two RS 232 serial ports, one for console from the integrated
management processor and one from the processor dependent hardware
bus (PDH)
- Factory integration of processors, memory, disk drives,
removable media, I/O cards, and HP Universal 10000 G2 series racks.
- Rackmountable into 19 inch cabinets-HP Universal 10000 G2 series
as well as many third party racks, including field integration into
existing HP System E racks
- Optional stand alone pedestal mount, field installation only.
- Three year warranty with next business day on site
|
|
| High Availability |
- N+1 Hot swap cooling
- One hot swap power supply-optional second power supply for N+1
protection
- Hot Plug PCI X I/O slots
- On line memory page deallocation
- ECC protected DDR2 memory
- Memory double chip spare to overcome single DRAM chip failures
- Dynamic Processor resilience and deallocation
- UPS power management
- Hot Plug internal disks
- Internal RAID support. See Standard Systems Features on previous
page and rx3600 Ordering Guide for various levels of RAID support
- Journal file system with HP-UX
- Auto reboot
- HP Serviceguard for HP-UX
- HP Serviceguard Extension for RAC for HP-UX
- HP Serviceguard Extension for SAP for HP-UX
- Serviceguard Manager for HP-UX and Linux Clusters
- HP Event Monitoring Service
- HA Monitors for HP-UX
- HA Toolkits for HP-UX and Linux
- HP Mirrordisk/UX
- Extended Campus Cluster, HP Metrocluster, and HP
Continentalclusters for HP-UX
- HP OpenVMS clusters
- HP Volume Shadowing for OpenVMS
- HP RMS Journaling for OpenVMS
- HP System Insight Manager (SIM) for proactive fault management
- Microsoft Cluster Service for Windows Server 2003 Enterprise and
Datacenter Edition
- HP StorageWorks Software for HP Integrity Servers running
Windows Server 2003 Enterprise Edition. Includes Cluster Extension
XP and EVA, Continuous Access, Business Copy and SQL Server Fast
Recovery
- HP StorageWorks Cluster Extension XP for Linux
|
|
| Security |
- Separate LAN for system management
- Password protection on console port
- Disablement of remote console ports
- SSL encryption on web console
|
|
Manageability - Deploy
|
- HP Ignite UX for installation and deployment of the operating
system
- HP Software Distributor UX for software and patch management
- HP Integrity Essentials Foundation Pack for Linux
- HP Integrity Essentials Foundation Pack for Windows including
Smart Setup CD for easy server setup and configuration
|
Manageability - Monitor
|
- Built in Integrity iLO 2 Management Processor for comprehensive
remote server management of HP-UX, Linux, Windows and OpenVMS
- HP Servicecontrol suite for HP-UX servers including tools for
system administration, asset management, and fault management
- HP-UX kernel configuration for easy, dynamic kernel parameter
changes
- HP System Insight Manager (SIM)
|
| Manageability - Optimize |
- Process Resource Manager for HP-UX resource management
- HP-UX Workload Manager for HP-UX workload management based upon
service level objectives
- HP OpenView GlancePlus Pack
- HP Intelligent Networking Pack for Windows
- HP Performance Management Pack for Windows
- Windows System Resource Manager (included with each copy of
Windows Server 2003 Enterprise Edition)
|
HP Integrity Systems Configuration
| Processor Configuration |
The HP Integrity rx3600 is
a symmetrical multiprocessing (SMP) server supporting up to two high
performance 64 bit dual core Intel Itanium processors. The dual core
Intel Itanium processor supports hyper threading. Each core of the
processor supports two threads. |
|
| Processor Details |
Dual core Intel Itanium 2
processors:
- 1.6 GHz with 18 MB Level 3 Cache, 9 MB per core processor
- 1.66 GHz with 18 MB Level 3 Cache, 9 MB per core 9140M processor
- 1.4 GHz with 12 MB Level 3 Cache, 6 MB per core processor
- 1.42 GHz with 12 MB Level 3 Cache, 6 MB per core 9120N processor
All processors support:
- Level 2 Cache: 1 MB Instruction/256 KB Data per core
- Level 1 Cache: 32 KB
- Four threads (two threads per core)
- Single bit cache error correction
- 50 bit physical addressing
- 64 bit virtual addressing
- 4 GB maximum page size
|
|
| Processor Configuration
Rules |
- Processors can be installed one at a time
- Processors must be installed in the following sequence: 0, 1
- Different speed and cache processors cannot be mixed in the same
system
|
|
|
Memory
Configuration
|
The HP Integrity rx3600
supports double data rate (DDR2) synchronous dynamic random access
memory (SDRAM) DIMMs with ECC and double chip spare protection. The HP
Integrity rx3600 can be ordered with one of the following two memory
carrier boards:
- AD124A-Supports from 2 GB (2×1GB DIMMs) minimum to 32 GB (8×4GB
DIMMs) maximum memory; 14.2 GB/s memory bandwidth. The AD124A can be
replaced with the AD125A to increase maximum memory beyond 32 GB and
to a maximum of 96 GB. Please note, there is no return credit for
the AD124A.
- AD125A-Supports from 2 GB (2×1GB DIMMs) minimum to 96 GB (24×4GB
DIMMs) maximum; 14.2 GB/s memory bandwidth
|
| Memory Loading Rules |
- Memory must be installed in groups of four DIMMs, also known as
quads; except for the 2-GB option, which is installed as 2 x 1-GB
DIMMs. Note: the 2-GB pair (2 x 1 GB DIMMs), product number AH350A,
is only supported with the 8-DIMM carrier (AD124A).
- Each DIMM in a memory option must consist of equal density DIMMs
- Memory can be ordered in quads of 4 GB (4×1GB), 8 GB (4×2GB), or
16 GB (4×4GB). There is also a 2-GB pair (2 x 1GB) supported with
the 8-DIMM carrier (AD124A).
- Minimum memory is 2 GB (2×1GB)
- Maximum memory is 96 GB, using six 16 GB memory quads in memory
carrier option AD125
- Memory must be loaded in the order depicted on the memory
carrier board
- Arrange DIMMs so that the DIMMs with the largest capacity are in
the lowest numbered slots.
- For best performance, all DIMM slots on both memory carrier
boards should be populated with the same size DIMM.
|
|
| HP
Integrity Systems Memory Options |
| Description |
Product
Number |
| 2-GB Chip Spare PC2-4200
ECC x4 single rank Registered DDR2 SDRAM memory pair (2×1GB DIMMs) |
AH350A |
| 4-GB Chip Spare PC2-4200
ECC x4 single rank Registered DDR2 SDRAM memory quad (4×1GB DIMMs) |
AB564A |
| 8-GB Chip Spare PC2-4200
ECC x4 single rank Registered DDR2 SDRAM memory quad (4×2GB DIMMs) |
AB565A |
| 16-GB Chip Spare PC2-4200
ECC x4 single rank Registered DDR2 SDRAM memory quad (4×4GB DIMMs) |
AB566A |
| Server Form Factor and
Rack Configuration |
The HP Integrity rx3600 is
a 4U rack optimized server. It is supported in HP 10000 G2 series
cabinets. For factory integration order AD053A with 0D1 feature code.
Sliding mounts and a cable management arm will be installed with the
server in a factory integrated rack.
The HP Integrity rx3600 can be installed in the field with the Field
Rack Kit (AD053A with B01 feature code). This field kit contains the
slide mounts, cable management arm, and all other hardware needed to
mount an rx3600 into a 19 inch cabinet.
Refer to the 10000 G2 Series Rack Best Practices Guide for
information on rack deployment, stabilization and transportation. Go to
http://www.hp.com/go/rackandpower for more information.
The rx3600 is also available in a stand alone, pedestal form factor
(AD054A). Kit will be shipped in the same box with the system and is
field installable only. |
|
| HP
Integrity Systems I/O Architecture |
The HP Integrity rx3600
supports two I/O backplane options in order to provide maximum
flexibility, I/O card availability, performance, scalability and
reliability. The two options are a PCI-X 2.0 Backplane (AD295A Option
Code 100) or a PCI-Express Backplane option (AD295A OptionCode 200).
Only one backplane per system is supported.
PCI-X 2.0 Backplane:
This backplane provides ten PCI X I/O slots, two of which are reserved
for Core I/O cards and eight which are available for I/O card expansion.
The Core I/O slots will always be filled with either an HP PCI X 8
Internal Port Serial Attached SCSI (SAS) host bus adapter (for HP UX and
OVMS systems) or an HP PCI X Smart Array (P600) 8 Internal Port Serial
Attached SCSI (SAS) card (for Windows and Linux systems) (slot #1) and a
PCI X dual port 10/100/1000Base TX LAN adapter (slot #2). A second host
bus adapter is supported as a core I/O controller, but is not available
for standard factory installation; it must be installed via Factory
Express or in the field. When a second host bus adapter is ordered, it
must be installed in slot #2, and the LAN adapter moved to slot #10.
HP-UX and OpenVMS based systems with PCI-X 2.0 Backplane:
Must choose the HP PCI X 8 Internal Port Serial Attached SCSI host bus
adapter for Core I/O controller (AB036B Option 006 or Option 106). If
factory configured RAID is not desired, select Option 006. If factory
configured RAID 1 is desired, select Option 106. RAID 1 only is
supported on the HP PCI X 8 Internal Port SAS host bus adapter. When
selecting Option 106, a minimum of 2 HDDs of the same size and speed are
required. A maximum of two internal RAID 1 volumes (2×2 HDDs) and a disk
for global hot spare, for a maximum of five disks in RAIDed arrays is
supported. A second PCI X 8 Internal Port Serial Attached SCSI host bus
adapter is supported. In this case each adapter is connected up to a
maximum of 4 drives, and the maximum number of disks supported in a
RAIDed array is four. The second PCI X 8. Internal Port SAS host bus
adapter is not available for standard factory installation; it must be
installed via Factory Express or in the field. Use AD348A #006 upgrade
product/option to order the second PCI X 8 Internal Port SAS host bus
adapter. When a second PCI X 8 Internal Port SAS host bus adapter is
installed in an rx3600, it must be located in slot #2, and the LAN
adapter moved to slot #10. Please see rx3600 Ordering Guide for factory
configuration details.
Windows and Linux based systems with PCI X 2.0 backplane:
Must choose the HP PCI X 8 port Smart Array (P600) Serial Attached SCSI
(SAS) controller for Core I/O controller (AB036B Option 100, or Option
500, or Option 510). Option 100 provides for factory configuration of
RAID 1 (requires a minimum of 2 HDDs). Option 500 provides for factory
configuration of RAID 5 (requires a minimum of 3 HDDs). Option 510
provides for factory configuration of RAID 6 (requires a minimum of 4
HDDs). All HDDs must be the same size and speed. Please see rx3600
Ordering Guide for details.
Remaining Eight (non-Core I/O) slots:
The two slots (#3 and #4) next to the Core I/O slots have their own
dedicated 64 bit 266 MHz PCI X bus and their own independent 2.1 GB/s
I/O channel. These slots should be used for high performance PCI X
cards, such as clustering interconnects or multi port storage adapters.
The next two slots (slots #5 and #6) each have their own dedicated 64
bit 133 MHz PCI X bus and their own independent 1.1 GB/s I/O channel.
The independent buses and I/O channels provide improved performance and
error containment. Independence protects each I/O card from bus hangs or
extended latencies due to the failure or high bandwidth demands of other
I/O cards. Independence also ensures that each I/O card can achieve
maximum throughput.
The remaining four slots (#7 through #10) share two 64 bit 66 MHz PCI
X buses, with two slots allocated to each bus. Each pair of slots shares
a 0.5 GB/s I/O channel.
NOTE: Hot-plug operations are not
supported with the Linux or OpenVMS operating systems nor in Core I/O
slots.
All I/O slots are keyed for I/O cards with 3.3V signaling. Cards that
use 5V signaling are not supported in the HP Integrity rx3600.
PCI-Express Backplane:
This backplane also provides ten I/O slots. There are two PCI-X Core I/O
slots; one PCI-X Core I/O slot will always have a PCI-X dual port
10/100/1000Base TX LAN adapter (slot #2), and one PCI-X Core I/O slot is
provided in the case that the HP PCI-X 8 Internal Port Serial Attached
SCSI (SAS) host bus adapter is chosen (slot #1) when ordering an HP-UX
or OpenVMS-based system, or if an HP PCI-X Smart Array (P600) 8 Internal
Port Serial Attached SCSI (SAS) card is chosen when ordering a Windows
or Linux-based system. If a PCI-Express 8-port Smart Array (P400,
supports only internal connection to SAS disks) Serial Attached SCSI
controller (for HP-UX, OpenVMS, Windows, or Linux) is chosen, or if a
PCI-Express 16-port (8 internal ports/8 external ports) Smart Array
(P800) Serial Attached SCSI controller (for Windows or Linux, also
supports connection to external SAS disks) is chosen, the PCI-X Core I/O
slot remains empty and the PCI-Express controller is installed in slot
#3.
Each port of a Serial Attached SCSI card can be connected to a Serial
Attached SCSI hard disk drive, therefore each HP PCI-X 8 port SAS card
supports eight hard disks drives.
HP-UX and OpenVMS based systems with PCI-Express Backplane:
These systems have the two choices for Core I/O controller; the HP PCI-X
8 Internal Port Serial Attached SCSI host bus adapter or the HP
PCI-Express 8 Internal Port Smart Array (P400) Serial Attached SCSI
controller.
- HP PCI X 8 Internal Port Serial Attached SCSI host bus adapter
(AB036B Option 006 or Option 106). If factory configured RAID is not
desired, select Option 006. If factory configured RAID 1 is desired,
select Option 106. RAID 1 only is supported on the HP PCI X 8
Internal Port SAS host bus adapter. When selecting Option 106, a
minimum of 2 HDDs of the same size and speed are required. A maximum
of two internal RAID 1 volumes (2×2 HDDs) and a disk for global hot
spare, for a maximum of five disks in RAIDed arrays is supported.
Please note that MirrorDisk/UX is available for SW Mirroring on all
HDDs in HP UX based systems and HP Volume Shadowing Level 1 for HDDs
in OpenVMS based systems.
A second PCI X 8 Internal Port Serial Attached SCSI host bus
adapter is supported. In this case each adapter is connected up to a
maximum of 4 drives, and the maximum number of disks supported in a
RAIDed array is four. The second PCI X 8 Internal Port SAS host bus
adapter is not available for standard factory installation; it must
be installed via Factory Express or in the field. Use AD348A #006
upgrade product/option to order the second PCI X 8 Internal Port SAS
host bus adapter. When a second PCI X 8 Internal Port SAS host bus
adapter is installed in an rx3600, it must be located in slot #2,
and the LAN adapter moved to slot #10. Please see rx3600 Ordering
Guide for factory configuration details.
NOTES:
A. PCI X 8 Internal Port Serial Attached SCSI host bus adapters
located in Slot 1 and Slot 2 is the only multiple Serial Attached
SCSI Core IO Controller configuration supported on rx3600 servers.
B. The recommended cabling for this configuration is:
- SAS 1B cable connected to SAS host bus adapter Slot 1 Port B.
- SAS 1A cable connected to SAS host bus adapter Slot 2 Port A.
C. Wake on LAN is not supported on Core IO LAN card when moved to
Slot #10.
- PCI-Express 8-port Smart Array (P400) Serial Attached SCSI
Controller (AB036B Option 130, or Option 530, or Option 540).
Requires PCI-Express Backplane (AD295A Option Code 200). Option Code
130 provides for factory configuration of RAID-1 (requires a minimum
of 2 HDD's). Option Code 530 provides for factory configuration of
RAID-5 (requires a minimum of 3 HDD's). Option Code 540 provides for
factory configuration of RAID-6 (requires a minimum of 4 HDD's). All
HDD's must be the same size and speed. Please see rx3600 Ordering
Guide for details. Note: MirrorDisk/UX is available for SW Mirroring
on all HDDs in HP-UX based systems and HP Volume Shadowing Level 1
for HDDs in OpenVMS-based systems. A maximum of one 8-port Smart
Array (P400) Serial Attached SCSI Core IO Controller is supported on
rx3600 servers.
Windows and Linux based systems with PCI-Express Backplane:
These system have three choices for Core I/O controller; the PCI-X 8
Internal Port Smart Array (P600) Serial Attached SCSI controller, or the
PCI-Express 8 Internal Port Smart Array (P400) Serial Attached SCSI
controller, or the PCI-Express 16-port (8 internal ports/8 external
ports) Smart Array (P800) Serial Attached SCSI controller. A maximum of
one of these Serial Attached SCSI Core IO Controllers is supported on
rx3600 servers.
- HP PCI-X 8 port Smart Array (P600) Serial Attached SCSI
controller (AB036B Option Code 100, or Option Code 500, or Option
Code 510). Option Code 100 provides for factory configuration of
RAID-1 (requires a minimum of 2 HDD's). Option Code 500 provides for
factory configuration of RAID-5 (requires a minimum of 3 HDD's).
Option Code 510 provides for factory configuration of RAID-6
(requires a minimum of 4 HDD's). All HDDs must be the same size and
speed. Please see rx3600 Ordering Guide for details.
- PCI-Express 8-port Smart Array (P400) Serial Attached SCSI
Controller (AB036B Option 130, or Option 530, or Option 540).
Requires PCI-Express Backplane (AD295A Option 200). Option 130
provides for factory configuration of RAID-1 (requires a minimum of
2 HDDs). Option 530 provides for factory configuration of RAID-5
(requires a minimum of 3 HDDs). Option 540 provides for factory
configuration of RAID-6 (requires a minimum of 4 HDDs). All HDDs
must be the same size and speed. Please see rx3600 Ordering Guide
for details.
NOTE: The P400 controller
supports a mixture of RAID-1 on two like drives and RAID-5 on five
like drives, and combining RAID-1 and RAID-5 is supported, but not
as factory integration.
- PCI-Express 16-port (8 internal ports/8 external ports) Smart
Array (P800) Serial Attached SCSI Controller (AB036B Option 150, or
Option 550, or Option 560). Requires PCI-Express Backplane (AD296A
Option 200). Option 150 provides for factory configuration of RAID-1
(requires a minimum of 2 HDDs). Option 550 provides for factory
configuration of RAID-5 (requires a minimum of 3 HDDs). Option 560
provides for factory configuration of RAID-6 (requires a minimum of
4 HDDs). All HDDs must be the same size and speed. Please see rx3600
Ordering Guide for details.
Remaining Eight (non-Core I/O) slots:
The two slots (#3 and #4) next to the Core I/O slots share a PCI-Express
x8 1.3-GB/s I/O channel. The next two slots (slots #5 and #6) each have
their own PCI-Express x8 2.6-GB/s I/O channel. The independent I/O
channels provide improved performance and error containment.
Independence protects each I/O card from bus hangs or extended latencies
due to the failure or high bandwidth demands of other I/O cards.
Independence also ensures that each I/O card can achieve maximum
throughput. These slots should be used for high performance PCI X cards,
such as clustering interconnects or multi port storage adapters.
The remaining four slots (#7 through #10) are PCI-X slots. Slots #7
and #8 each have their own dedicated 64 bit 133 MHz PCI X slot; slot #7
is 1.1 GB/s and #8 is .5 GB/s. Slots #9 and #10 share a 64-bit 66-MHz
PCI-X 0.5 GB/s I/O channel.
NOTE: Hot plug operations are not
supported with the Linux or OpenVMS operating systems or for the PCI X
Core I/O slots for any operating system. Hot plug operations are not
supported for any operating system in slots #3 or #4.
All I/O slots are keyed for I/O cards with 3.3V signaling. Cards that
use 5V signaling are not supported in the HP Integrity rx3600. |
|
|
| HP
Integrity Systems Supported I/O Cards |
| |
| Supported HP-UX I/O
Cards |
| I/O Card
|
Product Number
|
PCIe/
PCI-X
|
Boot Support
|
Connector Type(s)
|
Maximum Cards
PCI-X Backplane
|
Maximum Cards
PCI-Express Backplane
|
Special Notes
|
| Mass Storage Host Bus
Adapters |
| PCI 2 channel Ultra320
SCSI |
A7173A
|
PCI-X
|
Yes
|
VHDCI
|
8
|
4
|
|
| PCI-X 2 channel Smart
Array 6402 Ultra3201 |
A9890A
|
PCI-X
|
Yes
|
VHDCI
|
6
|
2
|
Requires minimum of 512 MB of memory and full length slot
|
PCI-X 4 channel Smart
Array 6404 Ultra3201
|
A9891A
|
PCI-X
|
Yes
|
VHDCI
|
6
|
1
|
Requires minimum of 512 MB of memory and full length slot
|
| PCI-X 266 MHz 1 channel 4
Gb/s Fibre Channel |
AB378B
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
|
| PCI-X 266 MHz 2 channel 4
Gb/s Fibre Channel |
AB379B
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
|
| PCIe Smart Array P800 |
AD335A
|
PCIe
|
No
|
Mini SAS
|
0
|
4
|
|
| PCIe-2-port 4-Gb/s Fibre
Channel |
AD300A
|
PCIe
|
Yes
|
LC
|
0
|
2
|
|
HP PCI2 1-port 4-Gb/s
Fibre Channel HBA
|
AD299A
|
PCIe
|
No
|
LC
|
0
|
2
|
|
| HP PCI2 2-port 4-Gb/s
Fibre Channel HBA |
AD355A
|
PCIe
|
No
|
LC
|
0
|
2
|
|
| PCIe 4Gb Fibre Channel /
GbE-T HBA combo |
AD221A |
PCIe |
Yes |
|
0 |
4 |
|
| PCIe 2-port 4Gb Fibre
Channel / 2-port GbE-T HBA combo |
AD222A |
PCIe |
Yes |
|
0 |
4 |
|
| PCIe 2-port 4Gb Fibre
Channel / 2-port GbE-SX HBA combo |
AD393A |
PCIe |
Yes |
|
0 |
4 |
|
| Local Area Network
(LAN) Adapters |
PCI-X 1-port 1000Base-T
(gigabit copper)
|
AD331A
|
PCI-X
|
Yes
|
RJ-45
|
8
|
4
|
|
| PCI-X 1-port 1000Base-SX
(gigabit fiber) |
AD332A
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
|
PCI-X 2-port 1000Base-T
|
A7012A
|
PCI-X
|
Yes
|
RJ-45
|
8
|
4
|
|
PCI-X 2-port 1000Base-SX
|
A7011A
|
PCI-X
|
Yes
|
Duplex SC
|
8
|
4
|
|
| PCI-X 2-port 4x Fabric
(HPC) Adapter1 |
AB286C
|
PCI-X
|
No
|
4x Infiniband Copper
|
8
|
4
|
For maximum performance, card should not be installed in a shared
slot. Requires a minimum of 512 MB memory.
|
| PCI-X 4-port 1000Base-T
Gbit Adapter |
AB545A
|
PCI-X
|
Yes
|
RJ-45
|
8
|
4
|
|
| PCI-X 1-Port 10GbE |
AB287A
|
PCI-X
|
Yes
|
DuplexLC
|
4
|
2
|
For best performance, recommend at least one processor core per card
installed in the system. Each card requires 512MB of memory. Card
cannot be installed in a shared slot.
|
| PCI-X 266-MHz 1-port 10GbE
|
AD385A
|
PCI-X
|
Yes
|
DuplexLC
|
4
|
2
|
For best performance, recommend at least one processor core per card
installed in the system. Each card requires 512 MB of memory. Card
cannot be installed in a shared slot.
|
| PCIe 2-port 4x Fabric
(PHC) Adapter
|
AD313A
|
PCIe
|
|
|
0
|
4
|
|
| PCIe 2-port 4X DDR Fast IB
HCA |
AH304A
|
PCIe
|
No
|
|
0
|
4
|
|
HP PCIe 2-port 1000Base-T
card
|
AD337A
|
PCIe
|
Yes
|
RJ-45
|
0
|
4
|
|
HP PCIe 2-port 1000Base-SX
card
|
AD338A
|
PCIe
|
Yes
|
Duplex SC
|
0
|
4
|
|
| HP NC364T PCIe 4PT Gigabit
Server Adapter |
AD339A |
PCIe |
Yes |
|
0 |
4 |
|
HP PCIe 2-port 1000Base-T
T1 card
|
AD380A
|
PCIe
|
Yes
|
RJ-45
|
0
|
4
|
|
| HP PCIe 2-port 1000Base-SX
T1 card |
AD381A
|
PCIe
|
Yes
|
Duplex SC
|
0
|
4
|
|
| HP PCI-e 10GbE SR card |
AD386A
|
PCIe
|
Yes
|
|
0
|
4
|
|
PCI 1000Base-T Gigabit
Ethernet Adpt
|
A6825A
|
PCIe
|
No
|
RJ-45
|
8
|
4
|
|
| PCI 1000Base-SX Gigabit
Ethernet Adpt |
A6847A
|
PCIe
|
No
|
Duplex SC
|
8
|
4
|
|
| HP
Integrity Systems Multi-Function Cards
(Mass Storage/LAN) |
PCI-X 2Gb Fibre Channel /
1000BaseSX
|
A9782A
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
For maximum performance, card should not be installed in a shared
slot.
|
| PCI-X 2Gb Fibre Channel /
1000BaseTX |
A9784A
|
PCI-X
|
Yes
|
1 LC, 1 RJ-45
|
|
4
|
For maximum performance, card should not be installed in a shared
slot.
|
| HP PCI-X 1-port 4-Gb Fibre
Channel/1-port 1000Base-T Adapter |
AD193A
|
PCI-X
|
Yes
|
1 LC, 1 RJ-45
|
8
|
4
|
|
| PCI-X 2-port 2-Gb Fibre
Channel/2-port 1-Gb Ethernet Adapter |
AB465A
|
PCI-X
|
Yes
|
2 LC, 2 RJ-45
|
8
|
4
|
|
| HP PCI-X 2-port 4-GB Fibre
Channel/2-port 1000Base-T Adapter |
AD194A
|
PCI-X
|
Yes
|
2 LC, 2 RJ-45
|
8
|
4
|
|
| PCI-X 2-port 1000BT/2-port
U320 SCSI Multifunction Adapter |
AB290A
|
PCI-X
|
Yes
|
SCSI - LVD/SE
LAN - RJ-45
|
6
|
2
|
Card cannot be in a shared slot with an AB551A graphics card. Requires
full length slot. |
| HP
Integrity Systems Wide Area Network
(WAN) Adapters |
2 port Programmable Serial
Interface
(PSI) X.25 / Frame Relay / SDLC |
J3525A |
PCI-X
|
No
|
RS-530, RS-232, V.35, RS-449 or X.21
|
8
|
4
|
|
| HP
Integrity Systems Additional Interface
Cards |
| HP OpenVMS, HP-UX PCI
Graphics Card |
AB551A
|
PCI-X
|
No
|
VGA
|
2
|
2
|
|
PCI 8-port Serial MUX
Adapter
|
AD278A
|
PCI-X
|
No
|
|
8
|
4
|
|
PCI 64-port Serial MUX
Adapter
|
AD279A
|
PCI-X
|
No
|
|
8
|
4
|
|
| 16-port RS-232 RJ45 Port
Module |
AD280A
|
|
No
|
4 per AD279A
|
N/A
|
N/A
|
AD280A #001 Port Module Power Supply, required on Port Module (3)
and Port Module (4) connected to an AD279A 64-port MUX adapter.
|
| 16-port RS-232 DB-25 Port
Module |
AD281A
|
|
No
|
4 per AD279A
|
N/A
|
|
AD281A #001 Port Module Power Supply, required on Port Module (3)
and Port Module (4) connected to an AD279A 64-port MUX adapter.
|
| |
| HP
Integrity Systems Supported OpenVMS I/O
Cards |
| I/O Card
|
Product Number
|
PCIe/
PCI-X
|
Boot Support
|
Connector Type(s)
|
Maximum Cards
PCI-X Backplane
|
Maximum Cards
PCI-Express Backplane
|
Special Notes
|
| Mass Storage Host
Bus Adapters |
| PCI 2 channel Ultra320
SCSI |
A7173A
|
PCI-X
|
Yes
|
VHDCI
|
4
|
4
|
No On Line Add and Replace support.
|
| PCI-X 2 channel Smart
Array 6402 Ultra3201 |
A9890A
|
PCI-X
|
Yes
|
VHDCI
|
2
|
2
|
Requires minimum of 512 MB of memory and full length slot
|
| PCI-X 4 channel Smart
Array 6404 Ultra3201 |
A9891A
|
PCI-X
|
Yes
|
VHDCI
|
1
|
1
|
Requires minimum of 512 MB of memory and full length slot
|
| PCI-X 266 MHz 1
channel 4 Gb/s Fibre Channel |
AB378B
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
|
| PCI-X 266 MHz 2
channel 4 Gb/s Fibre Channel |
AB379B
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
|
| PCIe Smart Array P800
|
AD335A
|
PCIe
|
No
|
Mini SAS
|
0
|
4
|
|
| PCIe 2-port 4-Gb/s
Fibre Channel |
AD300A
|
PCIe
|
Yes
|
LC
|
0
|
4
|
|
| Local Area Network
(LAN) Adapters |
| PCI-X 1 port
1000Base-T (gigabit copper) |
AD331A
|
PCI-X
|
No
|
RJ-45
|
8
|
4
|
|
| PCI-X 1 port
1000Base-SX (gigabit fiber) |
AD332A
|
PCI-X
|
No
|
LC
|
8
|
4
|
|
| PCI X 1 Port 10 GbE
|
AB287A
|
PCI-X
|
No
|
Duplex LC
|
2
|
2
|
|
PCI-X 2-port
1000Base-T
|
A7012A
|
PCI-X
|
No
|
RJ-45
|
|
4
|
|
PCI-X 2-port
1000Base-SX
|
A7011A
|
PCI-X
|
No
|
Duplex SC
|
|
4
|
|
| PCI-X 4-port
1000Base-T Gbit Adapter |
AB545A
|
PCI-X
|
No
|
RJ-45
|
3
|
3
|
|
| HP NC364T PCIe 4PT
Gigabit Server Adapter |
AD339A |
PCIe |
No |
|
0 |
4 |
|
| Multi-Function
Cards (Mass Storage/LAN) |
PCI-X 2Gb Fibre
Channel / 1000BaseSX
|
A9782A
|
PCI-X
|
Yes
|
LC
|
4
|
4
|
For maximum performance, card should not be installed in a
shared slot.
|
| PCI-X 2Gb Fibre
Channel / 1000BaseTX |
A9784A
|
PCI-X
|
Yes
|
1 LC, 1 RJ-45 |
|
4
|
For maximum performance, card should not be installed in a
shared slot.
|
| HP PCI-X 1-port 4-GB
Fibre Channel/1-port 1000Base-T Adapter |
AD193A
|
PCI-X
|
Yes
|
1 LC, 1 RJ 45
|
2
|
2
|
|
| PCI-X 2-port 2-Gb
Fibre Channel/2-port 1-Gb Ethernet Adapter |
AB465A
|
PCI-X
|
Yes
|
2 RJ-45
|
2
|
2
|
|
| HP PCI-X 2-port 4-GB
Fibre Channel/2-port 1000Base-T Adapter |
AD194A
|
PCI-X
|
Yes
|
2LC, 2 RJ 45
|
2
|
2
|
|
| PCI-X 2-port
1000BT/2-port U320 SCSI Multifunction Adapter |
AB290A
|
PCI-X
|
Yes
|
SCSI - LVD/SE
LAN - RJ-45
|
2
|
2
|
Requires full length slot. |
| Additional
Interface Cards |
| HP OpenVMS, HP UX PCI
Graphics Card |
AB551A
|
PCI
|
No
|
VGA
|
4
|
3
|
Field installation only. On PCI-X backplane can be installed in
slots 5, 6, 7, 9. On PCI-e backplane, can be installed in slots
7, 8, 9.. Slot 9 can be shared with core LAN in slot 10.
|
| |
| Supported Windows I/O
Cards |
| I/O Card
|
Product Number
|
PCIe/
PCI-X
|
Boot Support
|
Connector Type(s)
|
Maximum Cards
PCI-X Backplane
|
Maximum Cards
PCI-Express Backplane
|
Special Notes
|
| Mass Storage Host
Bus Adapters |
| PCI 2 channel Ultra320
SCSI |
A7173A
|
PCI-X
|
Yes
|
VHDCI
|
2
|
2
|
|
PCI-X Smart Array P600
Serial Attached SCSI (SAS) Controller (for external storage only)
|
337972-B21
|
PCI-X
|
Yes
|
SFF8470
|
6
|
4
|
A maximum of (4) may be ordered with #0D1, the remaining (2)
must be ordered without #0D1
|
512 MB cache memory
upgrade for SA640x and SA P600 controller
|
372538-B21
|
PCI-X
|
N/A
|
N/A
|
N/A
|
N/A
|
|
| PCI-X 266-MHz
2-channel 4-Gb/s Fibre Channel |
AB379B
|
PCI-X
|
Yes
|
LC
|
6
|
4
|
Replaces AB379A
|
PCI-X 266 MHz 1
channel 4 Gb/s Fibre Channel
|
AD167A
|
PCI-X
|
Yes
|
LC
|
6
|
4
|
|
PCI-X 266 MHz 2
channel 4 Gb/s Fibre Channel
|
AD168A
|
PCI-X
|
Yes
|
LC
|
6
|
4
|
|
| PCI-X 266 MHz 1
channel 4 Gb/s Fibre Channel |
AB429A
|
PCI-X
|
Yes
|
LC
|
6
|
4
|
|
| PCIe Smart Array P800 |
AD335A
|
PCIe
|
Yes
|
Mini SAS
|
0
|
4
|
|
| PCIe Smart Array 500 |
AH226A
|
PCIe
|
Yes
|
Mini SAS
|
0
|
4
|
|
| PCIe 2 port 4 Gb/s
Fibre Channel |
AD300A
|
PCIe
|
Yes
|
LC
|
0
|
4
|
|
| PCIe 1 port 4 Gb/s
Fibre Channel |
AE311A
|
PCIe
|
Yes
|
LC
|
0
|
4
|
|
| PCIe 1 port 4 Gb/s
Emulex Fibre Channel |
A8002A
|
PCIe
|
Yes
|
LC
|
0
|
4
|
|
| PCIe 2 port 4 Gb/s
Emulex Fibre Channel |
A8003A
|
PCIe
|
Yes
|
LC
|
0
|
4
|
|
| Local Area Network
(LAN) Adapters |
| PCI 2 port
Windows/Linux 1000Base-SX |
A9899A
|
PCI-X
|
No
|
LC
|
6
|
4
|
No On Line Add and Replace support.
|
| PCI 2 port
Windows/Linux 1000Base-TX |
A9900A
|
PCI-X
|
No
|
RJ-45
|
6
|
4
|
| |