HP Integrity rx6600 Server |
| |
|
HP Integrity rx6600 System Overview (Interior View)
|
|
|
| 1. |
Recessed Carrying Handles |
3. |
8 Hot Plug PCI-X 10 Slots (2 @ 266 MHz) |
| 2. |
Redundant Bulk Power |
4. |
Hot Swap Fans |
| HP Integrity rx6600 |
 |
| 1. |
7U Chassis |
3. |
4 Clamshell CPU Sockets |
| 2. |
16 SAS HDDs |
4. |
48 DDR2 DIMM Slots |
HP Integrity Servers Standard Features
| Minimum System |
- One 64-bit dual-core Intel Itanium 2 processor; either
1.6-GHz/24 MB cache, or 1.6 GHz/18 MB cache, or 1.4 GHz/12 MB cache;
or 1.6 GHz/24 MB 9150N processor, or 1.6 GHz/18 MB 9140N processor,
or 1.4 GHz/12 MB 9120N processor
- One I/O backplane. Either PCI-X 2.0 backplane with 8 available
slots or PCI-Express backplane with 8 available slots
- 2-GB PC2 4200 ECC×4 Single Rank Registered DDR2 SDRAMs (4×512MB
DIMMs)
- 24 DIMM slots (1×24 DIMM slot memory carrier board)
- One hot swap power supply
|
|
| Maximum Server Capacities |
- Four dual core 64 bit Intel Itanium 2 processors; either 1.6
GHz/24 MB cache, or 1.6 GHz/18 MB cache, or 1.4 GHz/12 MB cache; or
1.6 GHz/24 MB 9150N processor, or 1.6 GHz/18 MB 9140N processor, or
1.4 GHz/12 MB 9120N processor
- One I/O backplane. Either PCI-X 2.0 backplane with 8 available
slots or PCI-Express backplane with 8 available slots
- 192 GB PC2 4200 ECC×4 Single Rank Registered DDR2 SDRAMs (24×4
GB DIMMs)
- 48 DIMM slots (2×24 DIMM slot memory carrier boards)
- Sixteen Serial Attached SCSI (SAS) disk drives
- Two hot swap power supplies (two supplies enables redundancy)
|
|
| Standard System Features |
- Operating System support: HP UX 11i version 2 June 2006 Update,
HP UX 11i v3, Linux RHEL AS 4 U4 and SLES 10, OpenVMS V8.3 or higher
for Integrity Servers and Microsoft Windows Server 2003 Enterprise
and Datacenter Edition
- Choice of core storage card.
For HP-UX and OpenVMS-based systems: Must select one of two
choices: PCI-X 8 port Serial Attached SCSI (SAS) host bus adapter or
PCI-Express 8-port Smart Array (P400) Serial Attached SCSI
Controller:
1. The PCI-X 8-port Serial Attached SCSI (SAS) host bus
adapter: Card will be installed in reserved core PCI-X I/O slot #1.
This card supports up to two internal RAID 1 volumes (2×2 HDDs) and
a disk for global hot spare, for a maximum of five disks in RAIDed
arrays for HP UX and OpenVMS. The additional three drives (of the
maximum of eight drives supported) can be accessed normally, but not
configured for RAID. Factory set up of RAID 1 configurations is
supported. When a second SAS Controller is required to support disks
9 through 16, it cannot be factory configured for RAID (unless it is
done through Factory Express) . For customer/field configured RAID
arrays, the same limitations (two RAID 1 arrays and one global
hotspare) exist. The additional three HDDs (14 through 16) can be
accessed normally, but not configured for RAID. Please see rx6600
Ordering Guide for factory configuration details. Note: MirrorDisk/UX
is available for SW Mirroring on all HDDs in HP UX based systems and
HP Volume Shadowing Level 1 for HDDs in OpenVMS-based systems.
2. PCI-Express 8-port Smart Array (P400) Serial Attached SCSI
Controller: Requires PCI-Express Backplane (AD296A Option Code 200);
card will be installed in public slot #3, leaving 3 available
PCI-Express slots and 4 available PCI-X slots. This card supports
internal RAID-1, 5 and 6 configurations. RAID-1 requires a minimum
of two identical HDDs, RAID-5 requires a minimum of three identical
HDDs, and RAID-6 requires a minimum of four identical HDDs. When a
second core PCI-Express P400 RAID controller is required to support
disks 9 through 16, it will be installed in slot #4, leaving two
available PCI-Express slots and four available PCI-X slots. Second
core controller cannot be factory configured for RAID (unless it is
done through Factory Express). Please see rx6600 Ordering Guide for
factory configuration details.
NOTE: MirrorDisk/UX is available for SW Mirroring on all HDDs in
HP UX based systems and HP Volume Shadowing Level 1 for HDDs in
OpenVMS-based systems.
For Windows and Linux based systems: Must select one of three
choices: PCI-X 8 port Smart Array (P600) Serial Attached SCSI (SAS)
controller, or PCI-Express 8-port Smart Array (P400) Serial Attached
SCSI Controller, or PCI-Express 16-port Smart Array (P800) Serial
Attached SCSI Controller.
1. PCI-X 8-port Smart Array (P600) Serial Attached SCSI (SAS)
controller:
Card will be installed in reserved core PCI-X I/O slot #1. Supports
internal RAID 1, 5 and 6 configurations.. RAID 1 requires two
identical HDDs, RAID 5 requires three identical HDDs, and
RAID 6 requires four identical HDDs. Factory set up of RAID 1, 5 and
6 configurations with Smart Array SAS controller is also supported.
When a second SAS Controller is required to support disks 9 through
16, it cannot be factory configured for RAID (unless it is done
through Factory Express) . For customer/field configured RAID
arrays, all eight HDDs (9 through 16) can be configured for RAID
levels 1, 5 and 6 in any combination. Please see rx6600 Ordering
Guide for details.
2. PCI-Express 8-port Smart Array (P400) Serial Attached SCSI
(SAS) controller.
Requires PCI-Express Backplane (AD296A Option Code 200); card will
be installed in public slot #3, leaving 3 available PCI-Express
slots and 4 available PCI-X slots. This card supports internal
RAID-1, 5 and 6 configurations. RAID-1 requires a minimum of two
identical HDDs, RAID-5 requires a minimum of three identical HDDs,
and RAID-6 requires a minimum of four identical HDDs. When a second
core PCI-Express P400 RAID controller is required to support disks 9
through 16, it will be installed in slot #4, leaving two available
PCI-Express slots and four available PCI-X slots. Second core
controller cannot be factory configured for RAID (unless it is done
throughFactory Express). Please see rx6600 Ordering Guide for
factory configuration details.
3. PCI-Express 16-port Smart Array (P800) Serial Attached
SCSI (SAS) controller:
Requires PCI-Express Backplane (AD296A Option Code 200); card will
be installed in public slot #3, leaving 3 available PCI-Express
slots and 4 available PCI-X slots. This card supports internal and
external RAID-1, 5 and 6 configurations. RAID-1 requires a minimum
of two identical HDDs, RAID-5 requires a minimum of three identical
HDDs, and RAID-6 requires a minimum of four identical HDDs. When a
second core PCI-Express P800 RAID controller is required to support
disks 9 through 16, it will be installed in slot #4, leaving two
available PCI-Express slots and four available PCI-X slots. Second
core controller cannot be factory configured for RAID (unless it is
done through Factory Express). Please see rx6600 Ordering Guide for
factory configuration details.
- Core PCI-X dual port 10/100/1000Base TX LAN (with auto speed
sensing; RJ 45 connector, Wake On LAN support)
- Integrated iLO2 Management Processor for remote management and
HA monitoring
- Telnet and web console via 10/100Base TX management LAN (RJ 45
connector)
- Two RS 232 serial ports, one for console from the integrated
management processor and one from the processor dependent hardware
bus (PDH)
- Factory integration of processors, memory, disk drives,
removable media, I/O cards, and HP Universal 10000 G2 series racks.
- Rackmountable into 19 inch cabinets-HP Universal 10000 G2 series
as well as many third party racks, including field integration into
existing HP System E racks
- Optional stand alone pedestal mount, field installation only.
- Three year warranty with next business day on site.
|
|
| High Availability |
- N+1 Hot swap cooling
- One Hot swap power supply-optional second power supply for N+1
protection
- Hot Plug PCI X I/O slots (Note: Some I/O cards do not support
hot plugging. Please see Supported I/O card Table 3 this chapter for
details.)
- On line memory page deallocation
- ECC protected DDR2 memory
- Memory double chip spare to overcome single DRAM chip failures
- Dynamic Processor resilience and deallocation
- UPS power management
- Hot Plug internal disks
- Internal RAID support. See Standard Systems Features on previous
page and rx6600 Ordering Guide for various levels of RAID support.
- Journal file system with HP UX
- Auto reboot
- HP Serviceguard for HP UX
- HP Serviceguard Extension for RAC for HP UX
- HP Serviceguard Extension for SAP for HP UX
- Serviceguard Manager for HP UX and Linux Clusters
- HP Event Monitoring Service
- HA Monitors for HP UX
- HA Toolkits for HP UX and Linux
- HP Mirrordisk/UX
- Extended Campus Cluster, HP Metrocluster, and HP
Continentalclusters for HP UX
- HP OpenVMS clusters
- HP Volume Shadowing for OpenVMS
- HP RMS Journaling for OpenVMS
- HP System Insight Manager (SIM) for proactive fault management
- Microsoft Cluster Service for Windows Server 2003 Enterprise
Edition
- HP StorageWorks Software for HP Integrity Servers running
Windows Server 2003 Enterprise Edition. Includes Cluster Extension
XP and EVA, Continuous Access, Business Copy and SQL Server Fast
Recovery
- HP StorageWorks Cluster Extension XP for Linux
|
|
| Security |
- Separate LAN for system management
- Password protection on console port
- Disablement of remote console ports
- SSL encryption on web console
|
|
Manageability - Deploy
|
- HP Ignite UX for installation and deployment of the operating
system
- HP Software Distributor UX for software and patch management
- HP Integrity Essentials Foundation Pack for Linux
- HP Integrity Essentials Foundation Pack for Windows including
Smart Setup CD for easy server setup and configuration
|
Manageability - Monitor
|
- Built in Integrity iLO 2 Management Processor for comprehensive
remote server management of HP UX, Linux, Windows and OpenVMS
- HP Servicecontrol suite for HP UX servers including tools for
system administration, asset management, and fault management
- HP UX kernel configuration for easy, dynamic kernel parameter
changes
- HP System Insight Manager (SIM)
|
| Manageability - Optimize |
- Process Resource Manager for HP UX resource management
- HP UX Workload Manager for HP UX workload management based upon
service level objectives
- HP OpenView GlancePlus Pack
- HP Intelligent Networking Pack for Windows
- HP Performance Management Pack for Windows
- Windows System Resource Manager (included with each copy of
Windows Server 2003 Enterprise Edition)
|
HP Integrity Servers Configuration
| Processor Configuration |
The HP Integrity rx6600 is
a symmetrical multiprocessing (SMP) server supporting up to four high
performance 64 bit dual core Intel Itanium processors. The dual core
Intel Itanium processor supports hyper threading. Each core of the
processor supports two threads. |
|
| Processor Details |
Dual core Intel Itanium
processors:
- 1.6 GHz with 24 MB Level 3 Cache, 12 MB per core processor
- 1.6 GHz with 24 MB Level 3 Cache, 12 MB per core 9150N processor
- 1.6 GHz with 18 MB Level 3 Cache, 9 MB per core processor
- 1.6 GHz with 18 MB Level 3 Cache, 9 MB per core 9140N processor
- 1.4 GHz with 12 MB Level 3 Cache, 6 MB per core processor
- 1.4 GHz with 12 MB Level 3 Cache, 6 MB per core 9120N processor
All processors support:
- Level 2 Cache: 1 MB Instruction/256 KB Data per core
- Level 1 Cache: 32 KB
- Four threads (two threads per core)
- Single bit cache error correction
- 50 bit physical addressing
- 64 bit virtual addressing
- 4 GB maximum page size
|
|
| Processor Configuration
Rules |
- Processors can be installed one at a time
- Processors must be installed in the following sequence: 0, 1, 2,
and 3
- Different speed and different cache size processors cannot be
mixed in the same system
|
|
|
Memory
Configuration
|
The HP Integrity rx6600
supports double data rate (DDR2) synchronous dynamic random access
memory (SDRAM) DIMMs with ECC and double chip spare protection. The HP
Integrity rx6600 can be ordered with one of the following two memory
carrier boards:
- AD126A-Supports from 2 GB minimum to 96 GB maximum memory; 8.5
GB/s memory bandwidth. The AD126A can be replaced with the AD127A to
increase maximum memory beyond 96-GB and to a maximum of 192-GB, or
to increase memory bandwidth to 17.0 GB/s. Please note, there is no
return credit for the AD126A.
- AD127A-Supports from 2 GB minimum to 192 GB maximum memory; 17.0
GB/s memory bandwidth.
|
| Memory Loading Rules |
- Memory must be installed in groups of four DIMMs, also known as
quads
- Each quad must consist of equal density DIMMs
- Memory can be ordered in quads of 2 GB (4×512MB), 4 GB (4×1GB),
8 GB (4×2GB), or 16 GB (4×4GB)
- Minimum memory is 2 GB (4×512MB)
- Maximum memory is 192 GB, using twelve 16 GB memory quads in
memory carrier option AD127A
- Memory must be loaded in the order depicted on the memory
carrier board.
- Arrange DIMMs so that the quads with the largest capacity are in
the lowest numbered slots.
- For best performance, all DIMM slots on both memory carrier
boards should be populated with the same size DIMM.
|
| HP
Integrity Servers Memory Options |
| Description |
Product
Number |
| 2-GB chip spare PC2-4200
ECC x4 single rank Registered DDR2 SDRAM memory quad (4×512MB DIMMs) |
AB563A |
| 4-GB chip spare PC2-4200
ECC x4 single rank Registered DDR2 SDRAM memory quad (4×1GB DIMMs) |
AB564A |
| 8-GB chip spare PC2-4200
ECC x4 single rank Registered DDR2 SDRAM memory quad (4×2GB DIMMs) |
AB565A |
| 16-GB chip spare PC2-4200
ECC x4 single rank Registered DDR2 SDRAM memory quad (4×4GB DIMMs) |
AB566A |
| Server Form Factor and
Rack Configuration |
The HP Integrity rx6600 is
a 7U rack optimized server. It is supported in HP 10000 G2 series
cabinets. For factory integration order AD053A with 0D1 feature code.
Sliding mounts and a cable management arm will be installed with the
server in a factory integrated rack.
The HP Integrity rx6600 can be installed in the field with the Field
Rack Kit (AD053A with B01 feature code). This field kit contains the
slide mounts, cable management arm, and all other hardware needed to
mount an rx6600 into a 19 inch cabinet.
Refer to the 10000 G2 Series Rack Best Practices Guide for
information on rack deployment, stabilization and transportation. Go to
http://www.hp.com/go/rackandpower for more information.
The rx6600 is also available in a stand-alone, pedestal form factor
(AD308A). Kit will be shipped in a separate box for field installation
only. |
|
| I/O Architecture |
| The HP Integrity rx6600
supports two I/O backplane options in order to provide maximum
flexibility, I/O card availability, performance, scalability and
reliability. The two options are a PCI-X 2.0 Backplane (AD296A Option
Code 100) or a PCI-Express Backplane option (AD296A OptionCode 200).
Only one backplane per system is supported.
PCI-X 2.0 Backplane:
This backplane provides ten PCI X I/O slots, two of which are reserved
for Core I/O cards, and eight of which are available for I/O card
expansion. The Core I/O slots will always be filled with either an HP
PCI X 8 Internal Port Serial Attached SCSI (SAS) host bus adapter (for
HP UX and OVMS systems) or an HP PCI X Smart Array (P600) 8 Internal
Port Serial Attached SCSI (SAS) card (for Windows and Linux systems)
(slot #1) and a PCI X dual port 10/100/1000Base TX LAN adapter (slot
#2).
Each port of a Serial Attached SCSI card can be connected to a Serial
Attached SCSI hard disk drive. When more than eight hard disk drives are
required, a second HP PCI-X 8 port SAS card must be ordered. This second
SAS card will be installed in the second core I/O slot, and the PCI-X
dual port 10/100/1000Base TX LAN adapter will be moved out to a standard
I/O slot. Note that when the LAN adapter is moved out to a standard I/O
slot, Wake On LAN is not supported.
HP-UX and OpenVMS based systems with PCI-X 2.0 Backplane:
Must choose the HP PCI-X 8 Internal Port Serial Attached SCSI host bus
adapter for Core I/O controller (AB036B Option Code 006 or Option Code
106). If factory configured RAID is not desired, select Option Code 006.
If factory configured RAID-1 is desired, select Option Code 106. RAID-1
only is supported on the HP PCI-X 8 Internal Port SAS host bus adapter.
When selecting Option Code 106, a minimum of 2 HDD's of the same size
and speed are required. A maximum of two internal RAID 1 volumes (2×2
HDDs) and a disk for global hot spare, for a maximum of five disks in
RAIDed arrays is supported. The additional three drives (of the maximum
of eight drives supported on the controller) can be accessed normally,
but not configured for RAID. When from 9 to 16 HDD's are ordered, a
second SAS Controller is required to support disks 9 through 16. The
second controller cannot be factory configured for RAID (unless it is
done through Factory Express). For customer/field configured RAID
arrays, the same limitations (two RAID 1 arrays and one global hot
spare) exist. The additional three HDDs (14 through 16) can be accessed
normally, but not configured for RAID. Please see rx6600 Ordering Guide
for factory configuration details. Please note that MirrorDisk/UX is
available for SW Mirroring on all HDDs in HP-UX based systems and HP
Volume Shadowing Level 1 for HDDs in OpenVMS-based systems.
Windows and Linux based systems with PCI-X 2.0 Backplane:
Must choose the HP PCI-X 8 port Smart Array (P600) Serial Attached SCSI
(SAS) controller for Core I/O controller (AB036B Option 100, or Option
500, or Option 510). Option 100 provides for factory configuration of
RAID-1 (requires a minimum of 2 HDDs). Option 500 provides for factory
configuration of RAID-5 (requires a minimum of 3 HDDs). Option 510
provides for factory configuration of RAID-6 (requires a minimum of 4
HDDs). All HDDs must be the same size and speed. When from 9 to 16 HDDs
are ordered, a second SAS Controller is required to support disks 9
through 16. The second controller cannot be factory configured for RAID
(unless it is done through Factory Express) . Please see rx6600 Ordering
Guide for details.
Remaining Eight (non-Core I/O) slots:
The two slots (#3 and #4) next to the Core I/O slots have their own
dedicated 64 bit 266 MHz PCI X bus and their own independent 2.1 GB/s
I/O channel. These slots should be used for high performance PCI X
cards, such as clustering interconnects or multi port storage adapters.
The next two slots (slots #5 and #6) each have their own dedicated 64
bit 133 MHz PCI X bus and their own independent 1.1 GB/s I/O channel.
The independent buses and I/O channels provide improved performance and
error containment. Independence protects each I/O card from bus hangs or
extended latencies due to the failure or high bandwidth demands of other
I/O cards. Independence also ensures that each I/O card can achieve
maximum throughput.
The remaining four slots (#7 through #10) share two 64 bit 66 MHz PCI
X buses, with two slots allocated to each bus. Each pair of slots shares
a 0.5 GB/s I/O channel.
NOTE: Hot plug operations are not
supported with the Linux or OpenVMS operating systems or in the core I/O
slots with any operating system.
All I/O slots are keyed for I/O cards with 3.3V signaling. Cards that
use 5V signaling are not supported in the HP Integrity rx6600.
PCI-Express Backplane:
This backplane also provides ten I/O slots. There are two PCI X Core I/O
slots; one PCI X Core I/O slot will always have a PCI X dual port
10/100/1000Base TX LAN adapter (slot #2), unless a second storage
controller is required, in which case the second controller is
configured in slot #2 and the LAN card is moved out to public slot #10,
and one PCI X Core I/O slot is provided in the case that the HP PCI X 8
Internal Port Serial Attached SCSI (SAS) host bus adapter is chosen when
ordering an HP UX or OpenVMS based system, or if an HP PCI X Smart Array
(P600) 8 Internal Port Serial Attached SCSI (SAS) card is chosen (slot
#1) when ordering a Windows or Linux based system. If a PCI Express 8
port Smart Array (P400, supports only internal connection to SAS disks)
Serial Attached SCSI controller (supported with HP UX, OpenVMS, Windows,
and Linux) is chosen, or if a PCI Express 16 port (8 internal ports and
8 external ports) Smart Array (P800) Serial Attached SCSI controller
(for Windows and Linux only, also supports connection to external SAS
disks) is chosen, the PCI X Core I/O slot remains empty and the PCI
Express controller is installed in slot #3.
Each port of a Serial Attached SCSI card can be connected to a Serial
Attached SCSI hard disk drive. When more than eight hard disk drives are
required, a second 8 port Serial Attached SCSI card must be ordered. If
a PCI-X card is chosen, it will be installed in the reserved PCI-X core
I/O slot. If a PCI-Express card is chosen, it will be installed in slot
#4.
HP-UX and OpenVMS based systems with PCI-Express Backplane:
These systems have the two choices for Core I/O controller; the HP PCI-X
8 Internal Port Serial Attached SCSI host bus adapter or the HP
PCI-Express 8 Internal Port Smart Array (P400) Serial Attached SCSI
controller.
- HP PCI-X 8 Internal Port Serial Attached SCSI host bus adapter
(AB036B Option Code 006 or Option Code 106). If factory configured
RAID is not desired, select Option Code 006. If factory configured
RAID-1 is desired, select Option Code 106. RAID-1 only is supported
on the HP PCI-X 8 Internal Port SAS host bus adapter. When selecting
Option Code 106, a minimum of 2 HDD's of the same size and speed are
required. A maximum of two internal RAID 1 volumes (2×2 HDDs) and a
disk for global hot spare, for a maximum of five disks in RAIDed
arrays is supported. The additional three drives (of the maximum of
eight drives supported on the controller) can be accessed normally,
but not configured for RAID. When from 9 to 16 HDD's are ordered, a
second SAS Controller is required to support disks 9 through 16. The
second controller cannot be factory configured for RAID (unless it
is done through Factory Express). For customer/field configured RAID
arrays, the same limitations (two RAID 1 arrays and one global
hotspare) exist. The additional three HDDs (14 through 16) can be
accessed normally, but not configured for RAID. Please see rx6600
Ordering Guide for factory configuration details. Please note that
MirrorDisk/UX is available for SW Mirroring on all HDDs in HP-UX
based systems and HP Volume Shadowing Level 1 for HDDs in
OpenVMS-based systems.
- PCI-Express 8-port Smart Array (P400) Serial Attached SCSI
Controller (AB036B Option 130, or Option 530, or Option 540).
Requires PCI-Express Backplane (AD296A Option 200). Option 130
provides for factory configuration of RAID-1 (requires a minimum of
2 HDDs). Option 530 provides for factory configuration of RAID-5
(requires a minimum of 3 HDDs). Option 540 provides for factory
configuration of RAID-6 (requires a minimum of 4 HDDs). All HDDs
must be the same size and speed. When from 9 to 16 HDDs are ordered,
a second SAS Controller is required to support disks 9 through 16.
The second controller cannot be factory configured for RAID (unless
it is done through Factory Express) . Please see rx6600 Ordering
Guide for details.
Note: MirrorDisk/UX is
available for SW Mirroring on all HDDs in HP UX based systems and HP
Volume Shadowing Level 1 for HDDs in OpenVMS-based systems.
Windows and Linux based systems with PCI-Express Backplane:
These system have three choices for Core I/O controller; the PCI-X 8
Internal Port Smart Array (P600) Serial Attached SCSI controller, or the
PCI-Express 8 Internal Port Smart Array (P400) Serial Attached SCSI
controller, or the PCI-Express 16-port (8 Internal/8 External) Smart
Array (P800) Serial Attached SCSI controller.
- HP PCI-X 8 port Smart Array (P600) Serial Attached SCSI
controller (AB036B Option 100, or Option 500, or Option 510). Option
100 provides for factory configuration of RAID-1 (requires a minimum
of 2 HDDs). Option 500 provides for factory configuration of RAID-5
(requires a minimum of 3 HDDs). Option 510 provides for factory
configuration of RAID-6 (requires a minimum of 4 HDDs). All HDDs
must be the same size and speed. When from 9 to 16 HDDs are ordered,
a second SAS Controller is required to support disks 9 through 16.
The second controller cannot be factory configured for RAID (unless
it is done through Factory Express) . Please see rx6600 Ordering
Guide for details.
- PCI-Express 8-port Smart Array (P400) Serial Attached SCSI
Controller (AB036B Option 130, or Option 530, or Option 540).
Requires PCI-Express Backplane (AD296A Option 200). Option 130
provides for factory configuration of RAID-1 (requires a minimum of
2 HDDs). Option 530 provides for factory configuration of RAID-5
(requires a minimum of 3 HDDs). Option 540 provides for factory
configuration of RAID-6 (requires a minimum of 4 HDDs). All HDDs
must be the same size and speed. When from 9 to 16 HDDs are ordered,
a second SAS Controller is required to support disks 9 through 16.
The second controller cannot be factory configured for RAID (unless
it is done through Factory Express) . Please see rx6600 Ordering
Guide for details.
- PCI-Express 16-port Smart Array (P800) Serial Attached SCSI
Controller (AB036B Option 150, or Option 550, or Option 560).
Requires PCI-Express Backplane (AD296A Option 200). Option 150
provides for factory configuration of RAID-1 (requires a minimum of
2 HDDs). Option 550 provides for factory configuration of RAID-5
(requires a minimum of 3 HDDs). Option 560 provides for factory
configuration of RAID-6 (requires a minimum of 4 HDDs). All HDDs
must be the same size and speed. When from 9 to 16 HDDs are ordered,
a second SAS Controller is required to support disks 9 through 16.
The second controller cannot be factory configured for RAID (unless
it is done through Factory Express) . Please see rx6600 Ordering
Guide for details.
Remaining Eight (non-Core I/O) slots:
The two slots (#3 and #4) next to the Core I/O slots share a PCI-Express
x8 1.3-GB/s I/O channel. The next two slots (slots #5 and #6) each have
their own PCI-Express x8 2.6-GB/s I/O channel. The independent I/O
channels provide improved performance and error containment.
Independence protects each I/O card from bus hangs or extended latencies
due to the failure or high bandwidth demands of other I/O cards.
Independence also ensures that each I/O card can achieve maximum
throughput. These slots should be used for high performance PCI X cards,
such as clustering interconnects or multi port storage adapters.
The remaining four slots (#7 through #10) are PCI-X slots. Slots #7
and #8 each have their own dedicated 64 bit 133 MHz PCI-X channel; slot
#7 is 1.1 GB/s and slot #8 is 0.5 GB/s. Slots #9 and #10 share a 64-bit
66-MHz PCI-X 0.5 GB/s I/O channel.
Note:Hot plug operations are not
supported with the Linux or OpenVMS operating systems or in the PCI X
Core I/O slots with any operating system. Hot plug operations are not
supported for any operating system in slots #3 or #4
All I/O slots are keyed for I/O cards with 3.3V signaling. Cards that
use 5V signaling are not supported in the HP Integrity rx6600. |
|
|
| HP
Integrity Servers Supported I/O Cards |
| |
| Supported HP-UX I/O
Cards |
| I/O Card
|
Product Number
|
PCIe/
PCI-X
|
Boot Support
|
Connector Type(s)
|
Maximum Cards
PCI-X Backplane
|
Maximum Cards
PCI-Express Backplane
|
Special Notes
|
| Mass Storage Host Bus
Adapters |
|
|
|
|
|
|
|
| PCI 2 channel Ultra320
SCSI |
A7173A
|
PCI-X
|
Yes
|
VHDCI
|
8
|
4
|
|
| PCI-X 2 channel Smart
Array 6402 Ultra3201 |
A9890A
|
PCI-X
|
Yes
|
VHDCI
|
6
|
2
|
Requires minimum of 512-MB of memory and full length slot
|
| PCI-X 4 channel Smart
Array 6404 Ultra3201 |
A9891A
|
PCI-X
|
Yes
|
VHDCI
|
6
|
1
|
Requires minimum of 512-MB of memory and full length slot
|
| PCI-X 266 MHz 1 channel
4-Gb/s Fibre Channel |
AB378B
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
|
| PCI-X 266 MHz 2 channel
4-Gb/s Fibre Channel |
AB379B
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
|
| PCIe Smart Array P800 |
AD335A
|
PCIe
|
Yes
|
Mini SAS
|
0
|
4
|
|
| PCIe 2-port 4-Gb/s Fibre
Channel |
AD300A
|
PCIe
|
Yes
|
LC
|
0
|
2
|
|
| HP PCIe 1-port 4-Gb/s
Fibre Channel HBA |
AD299A
|
PCIe
|
No
|
LC
|
0
|
2
|
|
| HP PCIe 2-port 4-Gb/s
Fibre Channel HBA |
AD355A
|
PCIe
|
No
|
LC
|
0
|
2
|
|
| PCIe 4Gb Fibre Channel /
GbE-T HBA combo |
AD221A
|
PCIe
|
Yes
|
|
0
|
4
|
|
| PCIe 2-port 4Gb Fibre
Channel / 2-port GbE-T HBA combo |
AD222A
|
PCIe
|
Yes
|
|
0
|
4
|
|
| PCIe 2-port 4Gb Fibre
Channel / 2-port GbE-SX HBA combo |
AD393A
|
PCIe
|
Yes
|
|
0
|
4
|
|
| Local Area Network
(LAN) Adapters |
|
|
|
|
|
|
|
| PCI-X 1-port 1000Base-T
(gigabit copper) |
AD331A
|
PCI-X
|
No
|
RJ-45
|
8
|
4
|
|
| PCI-X 1-port 1000Base-SX
(gigabit fiber) |
AD332A
|
PCI-X
|
No
|
LC
|
8
|
4
|
|
| PCI-X 2-port 1000Base-T |
A7012A
|
PCI-X
|
Yes
|
RJ-45
|
8
|
4
|
|
| PCI-X 2-port 1000Base-SX |
A7011A
|
PCI-X
|
Yes
|
Duplex SC
|
8
|
4
|
|
| PCI X 2-port 4x Fabric
(HPC) Adapter1 |
AB286C
|
PCI-X
|
No
|
4x Infiniband Copper
|
8
|
4
|
For maximum performance, card should not be installed in a shared
slot.
Requires a minimum of 512-MB memory.
|
| PCI-X 4-port 1000Base-T
Gbit Adapter |
AB545A
|
PCI-X
|
Yes
|
RJ-45
|
8
|
4
|
|
| PCIe 4-port HP NC364T Gbit
Adapter |
AD339A
|
PCIe
|
Yes
|
|
0
|
4
|
|
| PCI-X 1-Port 10GbE |
AB287A
|
PCI-X
|
Yes
|
DuplexLC
|
4
|
2
|
For best performance, recommend at least one processor core per card
installed in the system. Each card requires 512MB of memory. Card
cannot be installed in a shared slot.
|
| PCI-X 266-MHz 1-port 10GbE |
AD385A
|
PCI X
|
Yes
|
Duplex LC
|
4
|
2
|
For best performance, recommend at least one processor core per card
installed in the system. Each card requires 512 MB of memory. Card
cannot be installed in a shared slot.
|
| PCIe 2-port 4x Fabric (PHC)
Adapter |
AD313A
|
PCIe
|
No
|
4x Infiniband Copper
|
0
|
4
|
Supported with HP-UX 11i v2 Only
|
| PCIe 2-port 4X DDR Fast IB
HCA |
AH304A
|
PCIe
|
No
|
|
0
|
4
|
|
| HP PCIe 2-port 1000Base-T
card |
AD337A
|
PCIe
|
Yes
|
RJ-45
|
0
|
4
|
|
| HP PCIe 2-port 1000Base-SX
card |
AD338A
|
PCIe
|
Yes
|
Duplex SC
|
0
|
4
|
|
| HP PCIe 2-port 1000Base-T
T1 card |
AD380A
|
PCIe
|
Yes
|
RJ-45
|
0
|
4
|
|
| HP PCIe 2-port 1000Base-SX
T1card |
AD381A
|
PCIe
|
Yes
|
Duplex SC
|
0
|
4
|
|
| HP PCI-e 10GbE SR card |
AD386A
|
PCIe
|
Yes
|
|
0
|
4
|
|
| PCI 1000Base-T Gigabit
Ethernet Adpt |
A6825A
|
PCI-X
|
No
|
RJ-45
|
8
|
4
|
|
| PCI 1000Base-SX Gigabit
Ethernet Adpt |
A6847A
|
PCI-X
|
No
|
Duplex SC
|
8
|
4
|
|
| Multi-Function Cards
(Mass Storage/LAN) |
PCI-X 2Gb Fibre Channel /
1000BaseSX
|
A9782A
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
For maximum performance, card should not be installed in a shared
slot.
|
| PCI-X 2Gb Fibre Channel /
1000BaseTX |
A9784A
|
PCI-X
|
Yes
|
1 LC, 1 RJ-45 |
|
4
|
For maximum performance, card should not be installed in a shared
slot.
|
| HP PCI-X 1-port 4-GB Fibre
Channel/1-port 1000Base-T Adapter |
AD193A
|
PCI-X
|
Yes
|
1 LC, 1 RJ-45
|
8
|
4
|
|
| PCI-X 2-port 2-Gb Fibre
Channel/2-port 1-Gb Ethernet Adapter |
AB465A
|
PCI-X
|
Yes
|
2LC, 2 RJ-45
|
8
|
4
|
|
| HP PCI-X 2-port 4-GB Fibre
Channel/2-port 1000Base-T Adapter |
AD194A
|
PCI-X
|
Yes
|
2LC, 2 RJ-45
|
8
|
4
|
|
| PCI-X 2-port 1000BT/2-port
U320 SCSI Multifunction Adapter |
AB290A
|
PCI-X
|
Yes
|
SCSI - LVD/SE
LAN - RJ-45
|
6
|
2
|
Card cannot be in a shared slot with an AB551A graphics card. Requires
full length slot. |
| Wide Area Network
(WAN) Adapters |
2 port Programmable Serial
Interface (PSI)
X.25/Frame Relay/SDLC |
J3525A |
PCI-X
|
No
|
RS-530, RS-232, V.35, RS-449 or X.21
|
8
|
4
|
|
| Additional Interface
Cards |
|
|
|
|
|
|
|
| HP OpenVMS, HP-UX PCI
Graphics Card |
AB551A
|
PCI-X
|
No
|
VGA
|
2
|
2
|
|
| PCI 8-port Serial MUX
Adapter |
AD278A
|
PCI-X
|
No
|
|
8
|
4
|
|
| PCI 64-port Serial MUX
Adapter |
AD279A
|
PCI-X
|
No
|
|
8
|
4
|
|
| 16-port RS-232 RJ45 Port
Module |
AD280A
|
PCI-X
|
No
|
4 per AD279A
|
N/A
|
N/A
|
AD280A #001 Port Module Power Supply, required on Port Module (3)
and Port Module (4) connected to an AD279A 64-port MUX adapter.
|
| 16-port RS-232 DB-25 Port
Module |
AD281A
|
PCI-X
|
No
|
4 per AD279A
|
N/A
|
|
AD281A #001 Port Module Power Supply, required on Port Module (3)
and Port Module (4) connected to an AD279A 64-port MUX adapter.
|
| |
| Supported OpenVMS I/O
Cards |
| I/O Card
|
Product Number
|
PCIe/
PCI-X
|
Boot Support
|
Connector Type(s)
|
Maximum Cards
PCI-X Backplane
|
Maximum Cards
PCI-Express Backplane
|
Special Notes
|
| Mass Storage Host
Bus Adapters |
| PCI 2 channel Ultra320
SCSI |
A7173A
|
PCI-X
|
Yes
|
VHDCI
|
4
|
4
|
No On Line Add and Replace support.
|
| PCI-X 2 channel Smart
Array 6402 Ultra3201 |
A9890A
|
PCI-X
|
Yes
|
VHDCI
|
2
|
2
|
Requires minimum of 512-MB of memory and full length slot
|
PCI-X 4 channel Smart
Array 6404 Ultra3201
|
A9891A
|
PCI-X
|
Yes
|
VHDCI
|
1
|
1
|
Requires minimum of 512-MB of memory and full length slot
|
| PCI-X 266 MHz 1
channel 4 Gb/s Fibre Channel |
AB378B
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
|
| PCI-X 266 MHz 2
channel 4 Gb/s Fibre Channel |
AB379B
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
|
| PCIe Smart Array P800 |
AD335A
|
PCIe
|
Yes
|
Mini SAS
|
0
|
4
|
|
| PCIe 2-port 4-Gb/s
Fibre Channel |
AD300A
|
PCIe
|
Yes
|
LC
|
0
|
4
|
|
| Local Area Network
(LAN) Adapters |
| PCI-X 1 port
1000Base-T (gigabit copper) |
AD331A
|
PCI-X
|
No
|
RJ-45
|
8
|
4
|
|
| PCI-X 1 port
1000Base-SX (gigabit fiber) |
AD332A
|
PCI-X
|
No
|
LC
|
8
|
4
|
|
| PCI X 1 Port 10GbE |
AB287A
|
PCI-X
|
No
|
Duplex LC
|
2
|
2
|
|
PCI-X 2-port
1000Base-T
|
A7012A
|
PCI-X
|
No
|
RJ-45
|
|
4
|
|
PCI-X 2-port
1000Base-SX
|
A7011A
|
PCI-X
|
No
|
Duplex SC
|
|
4
|
|
| PCI-X 4-port
1000Base-T Gbit Adapter |
AB545A
|
PCI-X
|
No
|
RJ-45
|
3
|
3
|
|
| PCIe 4-port HP NC364T
Gbit Adapter |
AD339A
|
PCIe
|
Yes
|
|
0
|
4
|
|
| Multi-Function
Cards (Mass Storage/LAN) |
PCI-X 2Gb Fibre
Channel / 1000BaseSX
|
A9782A
|
PCI-X
|
Yes
|
LC
|
4
|
4
|
For maximum performance, card should not be installed in a
shared slot.
|
| PCI-X 2Gb Fibre
Channel / 1000BaseTX |
A9784A
|
PCI-X
|
Yes
|
1 LC, 1 RJ-45 |
|
|
For maximum performance, card should not be installed in a
shared slot.
|
| HP PCI-X 1-port 4-GB
Fibre Channel/1-port 1000Base-T Adapter |
AD193A
|
PCI-X
|
Yes
|
1 LC, 1 RJ 45
|
2
|
2
|
|
| PCI-X 2-port 2-Gb
Fibre Channel/2-port 1-Gb Ethernet Adapter |
AB465A
|
PCI-X
|
Yes
|
2 RJ-45
|
2
|
2
|
|
| HP PCI-X 2-port 4-GB
Fibre Channel/2-port 1000Base-T Adapter |
AD194A
|
PCI-X
|
Yes
|
2LC, 2 RJ-45
|
2
|
2
|
|
| PCI-X 2-port
1000BT/2-port U320 SCSI Multifunction Adapter |
AB290A
|
PCI-X
|
Yes
|
SCSI - LVD/SE
LAN - RJ-45
|
2
|
2
|
Requires full length slot. |
Additional
Interface Cards
|
|
|
|
|
|
|
|
| HP OpenVMS, HP UX PCI
Graphics Card |
AB551A
|
PCI
|
No
|
VGA
|
4
|
3
|
Field installation only. On PCI-X backplane can be installed in
slots 5, 6, 7, 9. On PCI-e backplane, can be installed in slots
7, 8, 9.. Slot 9 can be shared with core LAN in slot 10.
|
| |
| Supported Windows I/O
Cards |
| I/O Card |
Product Number
|
PCIe/
PCI-X
|
Boot Support
|
Connector Type(s)
|
Maximum Cards
PCI-X Backplane
|
Maximum Cards
PCI-Express Backplane
|
Special Notes
|
| Mass Storage Host
Bus Adapters |
|
|
|
|
|
|
|
| PCI 2 channel Ultra320
SCSI |
A7173A
|
PCI-X
|
Yes
|
VHDCI
|
2
|
2
|
|
| PCI-X Smart Array P600
Serial Attached SCSI (SAS) Controller (for external storage only) |
337972-B21
|
PCI-X
|
Yes
|
SFF8470
|
6
|
4
|
A maximum of (4) may be ordered with #0D1, the remaining (2)
must be ordered without #0D1
|
| 512 MB cache memory
upgrade for SA640x and SA P600 controller |
372538-B21
|
PCI-X
|
N/A
|
N/A
|
N/A
|
N/A
|
|
| PCI-X 266 MHz 2
channel 4 Gb/s Fibre Channel |
AB379A
|
PCI-X
|
Yes
|
LC
|
6
|
4
|
|
| PCI-X 266-MHz
2-channel 4-Gb/s Fibre Channel |
AB379B
|
PCI-X
|
Yes
|
LC
|
6
|
4
|
Replaces AB379A
|
| PCI-X 266 MHz 1
channel 4 Gb/s Fibre Channel |
AD167A
|
PCI-X
|
Yes
|
LC
|
6
|
4
|
|
| PCI-X 266 MHz 2
channel 4 Gb/s Fibre Channel |
AD168A
|
PCI-X
|
Yes
|
LC
|
6
|
4
|
|
| PCI-X 266 MHz 1
channel 4 Gb/s Fibre Channel |
AB429A
|
PCIe
|
Yes
|
LC
|
6
|
4
|
|
| PCIe Smart Array P800 |
AD335A
|
PCIe
|
Yes
|
Mini SAS
|
0
|
4
|
|
| PCIe Smart Array P500 |
AH226A
|
PCIe
|